Read engine configuration live instead of asserting it in the dashboard
The engine subtitles were hardcoded: "FlashAttention + Q4 KV Cache" and "DynamicVRAM
+ Pinned Async Offload". The first turned out to be accurate -- OLLAMA_FLASH_ATTENTION
and OLLAMA_KV_CACHE_TYPE really are set -- which is worse than being wrong, because it
would have gone on looking accurate after the settings changed.
engines.py reads both engines' real configuration: the ollama service environment via
systemd, and ComfyUI's own /system_stats for version, allocator, VRAM mode and argv.
Exposed at GET /api/engines, as an MCP tool, and in the dashboard subtitles with the
full settings list as a tooltip.
The settings worth surfacing are the ones that dictate how this service must behave
and that previously had to be discovered by reading journald: OLLAMA_NUM_PARALLEL=1
is why an unload queues behind a running generation and is reported as deferred
rather than failed, and OLLAMA_MAX_LOADED_MODELS=1 is why every swap evicts the
previous model. Each is reported with that explanation attached.
Writing the tests found a bug in the new code: (system.get("python_version") or
"").split()[0] raises IndexError when ComfyUI omits the field, and the surrounding
except would have swallowed it and reported ComfyUI as entirely offline.
Tests: 192 (was 182).
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
15
README.md
15
README.md
@@ -111,6 +111,18 @@ only if the card actually needs it.
|
||||
* **Honest gain reporting**: gain against the profile's *current* setting is reported separately from the spread across values tried. Conflating them turns a flat result into a headline "+102%".
|
||||
* **Safety**: refuses to start while ComfyUI is executing, suspends the arbitrator's automatic profile switching for the duration (otherwise a diffusion benchmark trips `trigger_comfy_priority`, which reapplies the whole profile and overwrites the clock being measured), and restores the original profile in a `finally` block — including on exception or cancellation.
|
||||
|
||||
### 🔧 Live Engine Configuration (`engines.py`)
|
||||
* `GET /api/engines` reports the **real, current** configuration of both engines and what
|
||||
each setting implies for arbitration — because the settings that dictate this service's
|
||||
behaviour live outside its own codebase.
|
||||
* `OLLAMA_NUM_PARALLEL=1` is why a `keep_alive: 0` unload queues behind a running
|
||||
generation and is reported as *deferred* rather than failed. `OLLAMA_MAX_LOADED_MODELS=1`
|
||||
is why every swap evicts the previous model. Working these out originally meant reading
|
||||
journald and the systemd unit by hand.
|
||||
* The dashboard's engine subtitles now come from this endpoint. They were previously
|
||||
hardcoded — and happened to be accurate, which is worse than being wrong, since they
|
||||
would have kept looking accurate after the configuration changed.
|
||||
|
||||
### 🩺 Dependency Self-Check (`health.py`)
|
||||
* `GET /api/health` verifies **everything this service depends on**: NVML, passwordless
|
||||
sudo for `nvidia-smi`, fan control through the headless X server, overclock drift, the
|
||||
@@ -156,7 +168,7 @@ only if the card actually needs it.
|
||||
## 1a. Tests
|
||||
|
||||
```bash
|
||||
/home/drjones/comfy-mcp-venv/bin/python -m pytest tests/ -q # 182 passed in ~3.7s
|
||||
/home/drjones/comfy-mcp-venv/bin/python -m pytest tests/ -q # 192 passed in ~3.7s
|
||||
```
|
||||
|
||||
Hermetic: no GPU, no network, no sleeps. An autouse fixture stubs `overclock_manager._sh`
|
||||
@@ -264,6 +276,7 @@ The HyperSwap server runs on port `9090` by default. Interactive OpenAPI/Swagger
|
||||
| `/api/analytics/models` | `GET` | Recency/frequency model ranking used to prioritise the warm budget. |
|
||||
| `/api/history?durable=true` | `GET` | Swap history from the persistent store rather than the in-memory ring. |
|
||||
| `/api/db` | `GET` | Store location, row counts and how many hours of history are held. |
|
||||
| `/api/engines` | `GET` | Live Ollama and ComfyUI configuration, with what each setting implies for arbitration. |
|
||||
| `/api/health` | `GET` | Dependency self-check: NVML, sudo, fan control, drift, store, upstreams — each with impact and remediation. |
|
||||
|
||||
### Governor & Autotune Endpoints
|
||||
|
||||
Reference in New Issue